Format |
EIA-51d |
EIA-51p |
||
---|---|---|---|---|
Explosion-proof structure |
Flameproof structure |
Internal pressure explosion-proof structure |
||
Measurement principle |
Non-dispersive infrared absorption method |
|||
Measurement component |
CO, CO2,CH4, etc. |
|||
Measurement range |
Minimum range |
0-0.11vol% (by component) |
||
Maximum range |
0-100vol% (by component) |
|||
Options range |
100-90 ~ 50 vol% (by component) |
|||
Performance |
Repeatability |
Standard range |
Zero: ± full scale 0.5% |
|
Options range |
Zero: ± full scale 0.5% |
|||
Linearity |
Of full scale ± 1.0% |
|||
Drift※ 2 |
Zero: ± 2.0% of full scale / week span: ± 2.0% of full scale / week |
|||
Response time (from spectrometer entrance) |
T90= within 20 seconds |
|||
Sample gas |
Composition |
Flameproof structure |
· Oxygen concentration of 21% or less, no dust, a group of mist without and electrical equipment ⅡB, gas and steam corresponding to the temperature class T4 - air mixture, and hydrogen - it is less of a risk equivalent to the air mixture. |
|
Internal pressure explosion-proof structure |
· Oxygen concentration of 21% or less, no dust, corresponding to the equipment of the mist without-temperature grade T4, gas and steam - that it is a less of ignition temperature equivalent to the air mixture. |
|||
Pressure |
1.98kPa more |
|||
Flow rate |
500mL / min |
|||
Temperature |
Ambient temperature |
|||
Emission point |
Atmospheric release |
|||
Wetted Material |
SUS304, SUS316, FKM, CaF2,Au, etc. |
|||
External dimensions |
W540 × D395 × H456mm (including mounting plate) |
|||
Mass |
About 50kg |
|||
Display |
LED digital display concentration, status display |
|||
Calibration method |
Standard: manual calibration options: automatic calibration |
|||
Analog output※ 3 |
Output content |
Concentration output 1ch |
||
Output Specifications |
Insulation output DC 4-20mA (DC 0-16mA / 0-20mA, DC 0-1V / 0-5V / 1-5V / 0-10V optional specification) |
|||
Analog value alarm |
Any can be set in the range from -10% to + 110% of the span width of the output current / voltage |
|||
Contact output (option)※ 3 |
Output content |
Spectrometer alarm / spectrometer attention / calibration and maintenance in / measurement range |
||
Output Specifications |
DC30V / 0.1A (resistive load), dry contact, COM common operation when the contact is closed |
|||
Contact input (optional)※ 3 |
Input content |
Measurement range switching / automatic calibration sequence start |
||
Input Specifications |
Open when voltage: DC24V |
|||
Communication (optional)※ 3 |
Interface |
RS-485 |
||
Protocol |
Modbus®RTU※ 5 |
|||
Communication speed |
19200/9600/4800/2400/1200 selected from bps |
|||
Installation environment |
Installation location |
Interior installation |
||
Ambient temperature |
-5 ~ 40 ℃ (direct sunlight, that there is no radiant heat) |
|||
Relative humidity |
90% or less |
|||
Vibration |
Vibration such as pumps and near the fan should be installed large place is to avoid (100Hz, 0.3m / s2or less) |
|||
Dust |
Environmental standards below |
|||
Utility |
Power-supply voltage |
Rated AC100 ~ 120V ± 10%, or AC200 ~ 240V ± 10% (However, the maximum AC250V) |
||
Power frequency |
Rating 50 / 60Hz common ± 5% |
|||
Power consumption |
Power-190VA, steady-state about 80 ~ 140VA |
|||
Internal pressure explosion-proof protective gas※ 4 |
Composition: nitrogen pressure: 196 ~ 690kPa |
※ Please consult For information about one other measurement components.
※ 2 in the atmospheric pressure constant, ambient temperature change that of ± 5 ℃.
※ 3 shielded cable is required.
※ It is required at the time of the 4 internal pressure explosion-proof structure.
※ 5 Modbus is a registered trademark of Schneider Automation Inc..